Components in the Pneumatic Kit
parts may vary slightly from year to year
click to expand pictures
| Compressor | Relief Valve | Pressure Switch | Transducer | Tanks | Regulators | Directional Valves | Actuators | Fittings and Tubing |
|
Components for the Pneumatic Kit |
||||||
|
||||||
|
Thomas Compressor Battery operated - shown with Norgren Relief Valve installed in upper photo |
|
Norgren 16-004 Relief Valve
Used to relieve excess pressure from the compressor. The
pressure switch should be used to start and stop the compressor. The relief
valve is a safety backup. |
||||
![]() |
Nason
Pressure Switch Used to send signals to controller to start and stop the compressor |
|||||
![]() |
Clippard Tanks Used to lessen pulsations and
store reserve air (energy). |
|||||
![]() new addition Voltage output proportional to input pressure. |
Texas Instruments 5CP3-7 Pressure Transducer gives an output based on the input pressure. It could be used to monitor system pressure as shown in the pneumatic schematic or to monitor an individual circuit. |
|||||
![]() |
Norgren R07 Regulator
with gauge
Regulators are used for pressure control. Changing pressure changes the force of the
actuator. |
![]() |
Monnier Regulator with bracket Regulators are used for pressure control. Changing pressure changes the force of the
actuator. |
|||
|
Actuators One linear actuator is included in the kit. You may order up to three additional at no charge. One of those may be a rotary actuator and the added cylinders can be equipped with reed position sensing switches and magnetic pistons. |
||||||
|
Bimba on-line order form for additional linear or rotary actuators |
||||||
![]() |
Parker Linear Actuator Bimba Linear Actuators have the same mounting and external dimensions as the Parker Actuators |
![]()
|
Parker Clevis & Clevis Mounts |
|||
|
Bimba Pneu-Turn Rotary Actuator Engineering Information and typical applications in .pdf® format |
![]() |
Bimba Magnetic Reed Switches To be used as position sensors with Bimba Linear and Rotary Actuators - includes LED indicator - polarity sensitive |
|||
|
Valves Single solenoids stay shifted as long as current is applied to the solenoid. Double solenoids need only a momentary signal to shift and stay shifted until an opposing signal on the opposite coil is applied. All valves are internally piloted and need a minimum of 30 psig to operate. |
||||||
![]() ![]()
|
SMC Valves 4-way 2 position single solenoid
4-way 2 position double solenoid |
Bosch Rexroth
4-way
2 position single solenoid Valve Model 840 w/ Electrical Spade Connectors spade connectors |
||||
![]() ![]() ![]() |
Festo ECO VPLE18-M5H Valve 4-way, 2 position single solenoid shown with included connector shown without connector
|
|||||
|
Fittings and Tubing |
||||||
![]()
|
Parker Plug Valves Used to shut off the airflow. It may be used in either direction |
![]() |
Parker Pipe Fittings Used to connect components. Use teflon tape to assure leakproof joints |
|||
|
|
SMC Instant Fittings When pipe thread is used, teflon® tape should be used to minimize leaks |
![]() |
SMC Flow Control Valves Used to adjust the exhaust flow from an actuator to control speed |
|||